Home The Word Brain My Amedeo FAQ Privacy About   


Hanzi Hunter — ultra-fast Hanzi study

AbstractAbout
All 1,152 aioLingua characters • The 20 audio files.

→ aioLingua Online Edition:

→ aioLingua PDF:


  Dental Implants

  Free Subscription


Articles published in J Dent

Retrieve available abstracts of 208 articles:
HTML format



Single Articles


    November 2025
  1. DDS NVV, Dds APLDL
    Eight-year follow-up of oral health-related quality of life in anodontia patients after dental implant rehabilitation.
    J Dent. 2025 Nov 4:106207. doi: 10.1016/j.jdent.2025.106207.
    PubMed     Abstract available


  2. ZHANG J, Kong F, Wang W, Wang X, et al
    Reliability and validity of the quality of life with implant prostheses in China: A tool for assessing quality of life among implant-prostheses wearers.
    J Dent. 2025;162:106106.
    PubMed     Abstract available


  3. AMADOR BARBOSA I, Sergio Almeida Alves M, Rayse Zagalo de Almeida P, de Almeida Rodrigues P, et al
    Assessing the diagnostic and treatment accuracy of Large Language Models (LLMs) in Peri-implant diseases: A clinical experimental study.
    J Dent. 2025;162:106091.
    PubMed     Abstract available


  4. ROMANOS GE, Estrin NE
    Laser applications in peri-implantitis therapy: A narrative review.
    J Dent. 2025;162:106081.
    PubMed     Abstract available


  5. LI Q, Han R, Huang J, Liu CB, et al
    Hierarchical multi-label classification model for cbct-based extraction socket healing assessment and stratified diagnostic decision-making to assist implant treatment planning.
    J Dent. 2025;162:106045.
    PubMed     Abstract available


  6. CEVIK P, Yilmaz B, Kahveci C, Abou-Ayash S, et al
    Effect of scanned arch, level of impression, and impression technique on the accuracy of impressions for complete-arch implant-supported fixed dental prostheses.
    J Dent. 2025;162:106049.
    PubMed     Abstract available


  7. PERA F, Gibello U, Dalmasso L, Menini M, et al
    Evaluation of dynamic computer-assisted implant placement accuracy by means of a novel digital method: A feasibility clinical study.
    J Dent. 2025;162:106021.
    PubMed     Abstract available


  8. THOMAS NG, Junior FGS, Ninan N, Anil S, et al
    Bioglass in dentistry: A comprehensive review of current applications and innovative frontiers.
    J Dent. 2025;162:106017.
    PubMed     Abstract available


    October 2025
  9. KHEDER W, Leblouba M, Rego R, Hamdoon Z, et al
    Multicentre Validation and Clinical Interpretation of an Explainable Gradient-Boosting Model for Dental-Implant Survival/Failure Prediction.
    J Dent. 2025 Oct 8:106166. doi: 10.1016/j.jdent.2025.106166.
    PubMed     Abstract available


  10. CONTE A, Ghiraldini B, Denofrio PHF, Marcello-Machado RM, et al
    Supracrestal implant placement improves peri-implant health in T2DM patients: A randomized clinical trial.
    J Dent. 2025;161:106002.
    PubMed     Abstract available


  11. MARCERON T, Kumar A, Grigoriadis A, Campan P, et al
    Comparison of the accuracy of static and dynamic computer-assisted implant surgery in extraction sockets, encased healed sites, and distal extension: an in vitro study.
    J Dent. 2025;161:105985.
    PubMed     Abstract available


  12. GRANDE F, Nuytens P, Zahabiyoun S, Iocca O, et al
    Factors influencing the intraoral implant scan accuracy: a review of the literature.
    J Dent. 2025;161:105973.
    PubMed     Abstract available


  13. SANTAMARIA-LAORDEN A, Marugan AM, Andreu-Vazquez C, Orejas-Perez J, et al
    Complete arch implant capture using a photogrammetry algorithm and smartphone app: An in vitro study.
    J Dent. 2025;161:105969.
    PubMed     Abstract available


  14. LAHOUD P, Castro A, Walter E, Jacobs W, et al
    SealPrint: The anatomically replicated seal-and-support socket abutment technique A Proof-of-Concept with 12 months of follow-up.
    J Dent. 2025;161:105948.
    PubMed     Abstract available


  15. NEGREIROS WM, Sun TC, Jain S, Finkelman M, et al
    Precision of complete-arch digital implant scans using photogrammetry and intra-oral scanning. An in vivo cross-over study: Complete-Arch Implant Scans: Photogrammetry vs IOS.
    J Dent. 2025;161:105928.
    PubMed     Abstract available


    September 2025
  16. KIM J, Kim JY, Choi EJ, Jo HG, et al
    Is medication-related osteonecrosis of the jaw around dental implants associated with the implant design and prosthesis characteristics?
    J Dent. 2025;163:106133.
    PubMed     Abstract available


  17. GANZ SD
    Fully-Guided Placement of Dental Implants Utilizing Nasopalatine Canal Fixation in a Novel Rotational Path Surgical Template Design: A Retrospective Case Series.
    J Dent. 2025 Sep 3:106085. doi: 10.1016/j.jdent.2025.106085.
    PubMed     Abstract available


  18. PARK JS, Alshehri YFA, Kruger E, Villata L, et al
    Accuracy of digital versus conventional implant impressions in partially dentate patients: A systematic review and meta-analysis.
    J Dent. 2025;160:105918.
    PubMed     Abstract available


  19. KIVOVICS M, Orsos M, Birton NE, Vegh D, et al
    A retrospective study evaluating the success of implant-supported overdentures following fully-guided static computer assisted implant surgery.
    J Dent. 2025;160:105924.
    PubMed     Abstract available


  20. REIS INRD, Huaman-Mendoza AA, Ramadan D, Honorio HM, et al
    The prevalence of peri-implant mucositis and peri-implantitis based on the world workshop criteria: A systematic review and meta-analysis.
    J Dent. 2025;160:105914.
    PubMed     Abstract available


  21. KOHAL RJ, Komine F, Lith A, Spies BC, et al
    One-piece zirconia oral implants supporting three-unit fixed dental prostheses: Ten-year results from a prospective case series.
    J Dent. 2025;160:105911.
    PubMed     Abstract available


  22. REIS INRD, Jue A, Wolvius E, Pijpe J, et al
    Analysis of bone dimensional stability after two-stage maxillary sinus floor augmentation with autogenous bone versus bovine bone mineral combined with autogenous bone chips: results from a 1-year multicenter split-mouth randomized controlled trial.
    J Dent. 2025;160:105889.
    PubMed     Abstract available


  23. DA SILVA LJ, Vieira HT, Morel LL, Possebon APDR, et al
    Can combination syndrome influence functional performance and peri-implant bone remodeling in mandibular overdenture users? Results from a 5-year cohort study.
    J Dent. 2025;160:105878.
    PubMed     Abstract available


  24. WU BZ, Yang W, Liu MY, Ma FF, et al
    Evaluating the accuracy of a novel marker-free registration technique for dynamic computer-assisted implant surgery: An in vitro study.
    J Dent. 2025;160:105876.
    PubMed     Abstract available


  25. JAIN S, Nagy K, Bhalerao A
    Accuracy and safety of dynamic navigation vs. freehand approach in indirect sinus lift and immediate implant placement: A split mouth clinical study.
    J Dent. 2025;160:105866.
    PubMed     Abstract available


  26. TIRONE F, Salzano S, Rolando E, Pirja DA, et al
    Relation between CAD dimensional parameters and framework fracture in zirconia full arch implant rehabilitation: An observational cohort study.
    J Dent. 2025;160:105851.
    PubMed     Abstract available


  27. SRINIVASAN M, Curado TFF, Kamnoedboon P, Srisanoi K, et al
    Peri-implantitis and peri?implant oral malignancies: A systematic review and meta-analysis of diagnostic challenges and potential associations.
    J Dent. 2025;160:105773.
    PubMed     Abstract available


    August 2025
  28. CHE SA, Yang BE, Park SY, On SW, et al
    Clinical Evaluation of AI-Based Three-Dimensional Dental Implant Planning: A Multicenter Study.
    J Dent. 2025 Aug 26:106066. doi: 10.1016/j.jdent.2025.106066.
    PubMed     Abstract available


  29. QIU S, Yu X, Wu Y
    Application of Artificial Intelligence in Bone Quality and Quantity Assessment for Dental Implant Planning: A Scoping Review.
    J Dent. 2025 Aug 8:106027. doi: 10.1016/j.jdent.2025.106027.
    PubMed     Abstract available


  30. CRUZ RKS, Freire GCB, Viana JCM, Simao CEPCN, et al
    Efficacy of implantoplasty in the treatment of peri-implantitis: A 24-month randomized controlled clinical trial.
    J Dent. 2025;159:105844.
    PubMed     Abstract available


  31. JAVED F, Romanos GE
    Efficacy of photobiomodulation in the management of experimentally-induced peri?implant osseous defects: An evidence-based review of studies on animal-models.
    J Dent. 2025;159:105833.
    PubMed     Abstract available


  32. BOSE MWH, Atay E, Beuer F, Bruhnke M, et al
    Accuracy of two static computer-assisted implant surgery systems in partially edentulous patients: A randomized clinical trial using intraoral scan data.
    J Dent. 2025;159:105814.
    PubMed     Abstract available


  33. GRANDE F, Mosca Balma A, Mussano F, Catapano S, et al
    Effect of Implant Scan Body type, Intraoral scanner and Scan Strategy on the accuracy and scanning time of a maxillary complete arch implant scans: an in vitro study.
    J Dent. 2025;159:105782.
    PubMed     Abstract available


    July 2025
  34. DE LAURETIS A, Santacroce M, Ellingsen JE, Lyngstadaas SP, et al
    Surface-specific outcomes of mechanical debridement with titanium, chitosan and nitinol brushes on titanium dental implant surfaces.
    J Dent. 2025;162:106010.
    PubMed     Abstract available


  35. YANG W, Weng JL, Sun F, Jiao H, et al
    Evaluation of the accuracy of dynamic navigation versus robot-assisted dental implant placement in models with one missing tooth or multiple missing teeth with a free-end: an in vitro study.
    J Dent. 2025 Jul 8:105962. doi: 10.1016/j.jdent.2025.105962.
    PubMed     Abstract available


  36. KUHLMEY AE, Yassine J, Schmidt F, Beuer F, et al
    Fracture resistance of a second generation of zirconia implants after artificial ageing: An in vitro study.
    J Dent. 2025;158:105784.
    PubMed     Abstract available


    June 2025
  37. JIN C, Zhu Z, Guo Y, Zhao S, et al
    Comparative Accuracy of Active and Passive Dynamic Navigation Systems in Dental Implant Surgery: A Retrospective Study.
    J Dent. 2025 Jun 25:105938. doi: 10.1016/j.jdent.2025.105938.
    PubMed     Abstract available


  38. YAZIGI C, Passia N, Wolfart S, Kern M, et al
    Single mandibular midline-implant supported overdentures: Fifteen-year clinical outcome.
    J Dent. 2025;157:105768.
    PubMed     Abstract available


  39. AYYILDIZ H, Eken S, Terzioglu AG, Guler Ayyildiz B, et al
    Evaluation of the impact of periodontitis susceptibility on perI-implant marginal bone level changes: A longitudinal retrospective study.
    J Dent. 2025;157:105757.
    PubMed     Abstract available


  40. LUO Y, Yu M, Li B, Song W, et al
    Accuracy of robot and template systems in implant cases: A retrospective non-randomized controlled study.
    J Dent. 2025;157:105736.
    PubMed     Abstract available


  41. FERREIRA ACRM, Nogueira TE, de Oliveira BS, Dias AP, et al
    Changes in stability and marginal bone level around implants with hydrophilic and hydrophobic surfaces for posterior tooth replacement: A 1-year randomized clinical trial.
    J Dent. 2025;157:105696.
    PubMed     Abstract available


  42. ZHAO W, Wang Y, Ma J, Su Y, et al
    In vitro evaluation of six intraoral scanners for cone beam computed tomography data registration in robotic-assisted implant surgery: Impact of scanning experience.
    J Dent. 2025;157:105684.
    PubMed     Abstract available


    May 2025
  43. MEMENGA-NICKSCH S, Marschner F, Thomas NH, Holzwart D, et al
    Systematic review and meta-analysis on marginal bone loss of dental implants placed in augmented or pristine bone sites: Findings from clinical long-term studies.
    J Dent. 2025 May 6:105808. doi: 10.1016/j.jdent.2025.105808.
    PubMed     Abstract available


  44. SHU Q, Liu Q, Chen D, Zhou Y, et al
    Surgical protocol affecting robotic implant accuracy: Ex-vivo study.
    J Dent. 2025;156:105722.
    PubMed     Abstract available


  45. TOLSTAYA E, Tichy A, Paris S, Schwendicke F, et al
    Improving machine learning-based bitewing segmentation with synthetic data.
    J Dent. 2025;156:105679.
    PubMed     Abstract available


  46. BRAKOC J, Todorovic A, Mangano FG, Glisic M, et al
    Accuracy of intraoral photogrammetry versus direct digital implant impressions in the fully edentulous lower jaw: An in vitro study.
    J Dent. 2025;156:105654.
    PubMed     Abstract available


    April 2025
  47. TRABOULSI-GARET B, Jorba-Garcia A, Bara-Casaus J, Camps-Font O, et al
    Accuracy of freehand versus dynamic computer-assisted zygomatic implant placement: An in-vitro study.
    J Dent. 2025;155:105620.
    PubMed     Abstract available


  48. WU Z, Chen Y, Yu X, Wang F, et al
    Prediction of pink esthetic score using deep learning: A proof of concept.
    J Dent. 2025;155:105601.
    PubMed     Abstract available


    March 2025
  49. RUSTICHINI F, Romolini R, Salmi MC, Gennai L, et al
    Implant-supported full-arch fixed dental prostheses manufactured through a direct digital workflow using a calibrated splinting framework: A retrospective clinical study.
    J Dent. 2025;154:105605.
    PubMed     Abstract available


  50. ZHAO N, Zhu R, Liao L, Zhang M, et al
    Application of a semi-active robotic system for implant placement in atrophic posterior maxilla: A retrospective case series.
    J Dent. 2025;154:105593.
    PubMed     Abstract available


    February 2025
  51. ELBORAEY MO, Alqutaibi AY, Aboalrejal AN, Borzangy S, et al
    Regenerative approaches in alveolar bone augmentation for dental implant placement: Techniques, biomaterials, and clinical decision-making: A comprehensive review.
    J Dent. 2025 Feb 3:105612. doi: 10.1016/j.jdent.2025.105612.
    PubMed     Abstract available


  52. ELBASHTI ME, Naveau A, Spies B, Hillebrecht AL, et al
    Feasibility, trueness and precision of intraoral scanners in digitizing maxillectomy defects with exposed zygomatic implants in situ: An in vitro 3D comparative study.
    J Dent. 2025;153:105557.
    PubMed     Abstract available


  53. SCHAFER T, Matzener KJ, Jung RE, Ozcan M, et al
    Load-bearing capacity of screw-retained fixed dental prostheses made of monolithic zirconia on different abutment designs and abutment-free implant connection.
    J Dent. 2025;153:105561.
    PubMed     Abstract available


  54. KERNEN-GINTAUTE A, Akulauskas M, Kernen F, Zitzmann NU, et al
    Accuracy of digital and conventional implant impressions in edentulous jaws: A clinical comparative study.
    J Dent. 2025;153:105559.
    PubMed     Abstract available


  55. DONMEZ MB, Cakmak G, Schimmel M, Bayadse M, et al
    Scan accuracy of recently introduced wireless intraoral scanners in different fixed partial denture situations.
    J Dent. 2025;153:105558.
    PubMed     Abstract available


  56. LIMONES A, Cakmak G, Fonseca M, Roccuzzo A, et al
    Impact of scanning interruptions on accuracy of implant-supported full-arch scans: An in-vitro pilot study.
    J Dent. 2025;153:105503.
    PubMed     Abstract available


  57. LU W, Wu Y, Yao X, Zhang C, et al
    Effect of different wound closure interventions on the clinical outcomes following immediate implant placement in the aesthetic area: A network meta-analysis based on thirty-four studies.
    J Dent. 2025;153:105488.
    PubMed     Abstract available


  58. LIDANI R, Lisboa MC, Cadore A, Philippi AG, et al
    Influence of the extension of the anchorage surface of mandibular overdentures on patient's quality of life and satisfaction: 5-year follow-up of a randomized clinical trial.
    J Dent. 2025;153:105491.
    PubMed     Abstract available


  59. NEUSCHITZER M, Toledano-Serrabona J, Jorba-Garcia A, Bara-Casaus JJ, et al
    Comparative accuracy of dCAIS and freehand techniques for immediate implant placement in the maxillary aesthetic zone: An in vitro study.
    J Dent. 2025;153:105472.
    PubMed     Abstract available


  60. DEMIREL M, Diken Turksayar AA, Donmez MB, Schimmel M, et al
    Evaluation of the fabrication trueness and internal fit of additively manufactured two-piece zirconia abutments with different build orientations compared to subtractively manufactured abutments.
    J Dent. 2025;153:105470.
    PubMed     Abstract available


  61. AL-JARSHA MY, Diao Y, Zhao G, Imran MA, et al
    Dynamic navigation-guided robotic placement of zygomatic implants.
    J Dent. 2025;153:105463.
    PubMed     Abstract available


    January 2025
  62. BERGE TLL, Lygre GB, Kubon B, Lie SA, et al
    Key Factors for a National Dental Implant Registry.
    J Dent. 2025 Jan 31:105603. doi: 10.1016/j.jdent.2025.105603.
    PubMed     Abstract available


  63. PAN Y, Dai X, Tsoi JK, Lam WY, et al
    Effect of shape and size of implant scan body on scanning accuracy: An in vitro study.
    J Dent. 2025;152:105498.
    PubMed     Abstract available


  64. MICHAUD PL, Talmazov G, Dort H
    Are patient-reported outcomes improved by implant-assisted maxillary prostheses compared to conventional maxillary dentures? A systematic review.
    J Dent. 2025;152:105490.
    PubMed     Abstract available


  65. DU C, Peng P, Guo X, Wu Y, et al
    Combined static and dynamic computer-guided surgery for prosthetically driven zygomatic implant placement.
    J Dent. 2025;152:105453.
    PubMed     Abstract available


  66. LO-SARDO A, Preciado-Uribe A, Del Rio-Highsmith J, Aragoneses-Lamas JM, et al
    Modulators of oral health-related quality of life of maxillary implant overdenture users, analysed with the QoLIP-10, QoLDAS-9, and QoLFAST-10 specific questionnaires.
    J Dent. 2025;152:105438.
    PubMed     Abstract available


    December 2024
  67. CAPONIO VCA, Sharma A, Musella G, Perrotti V, et al
    Survival of dental implants placed in a postgraduate educational setting: a retrospective cohort study.
    J Dent. 2024;153:105531.
    PubMed     Abstract available


  68. BONFANTI-GRIS M, Ruales E, Salido MP, Martinez-Rus F, et al
    Artificial Intelligence for Dental Implant Classification and Peri-Implant Pathology Identification in 2D Radiographs: A Systematic Review.
    J Dent. 2024 Dec 14:105533. doi: 10.1016/j.jdent.2024.105533.
    PubMed     Abstract available


  69. TALLARICO M, Zadrozny L, Pia F, Marzio AD, et al
    An in-vitro study on accuracy of modular templates used to fully guide implants in combination with bone reduction for complete arch restorations: Experts versus students.
    J Dent. 2024;151:105437.
    PubMed     Abstract available


  70. GAO Y, Ma J
    Prevention of retrograde peri-implantitis caused by pulpal/periapical lesions in adjacent teeth: A literature review.
    J Dent. 2024;151:105434.
    PubMed     Abstract available


  71. WU HK, Leung S, Chen H, Kong Q, et al
    Effect of prefabricated auxiliary devices in different optical properties and shapes on the accuracy of intraoral scanning of the edentulous arch with multiple implants: An in-vitro study.
    J Dent. 2024;151:105430.
    PubMed     Abstract available


  72. LI K, Li T, Guo G, Liu L, et al
    Dynamic navigation vs. static navigation in implant placement: A meta-analysis.
    J Dent. 2024;151:105395.
    PubMed     Abstract available


  73. DINCER G, Molinero-Mourelle P, Donmez MB, Kahveci C, et al
    Scan accuracy of wireless intraoral scanners while digitizing a combined scan body-healing abutment system.
    J Dent. 2024;151:105413.
    PubMed     Abstract available


  74. OH JM, Kim Y, Lee HS, Son H, et al
    Paired transcriptional analysis of periodontitis and peri-implantitis within same host: A pilot study.
    J Dent. 2024;151:105366.
    PubMed     Abstract available


    November 2024
  75. FIORE AD, Stellini E, Monaco C, Yilmaz B, et al
    Clinical outcome of monolithic zirconia on bonded or mechanically retained prefabricated titanium-base: A 4-year retrospective study.
    J Dent. 2024;150:105350.
    PubMed     Abstract available


  76. HAUSCHILD U, Lerner H, Weigl P, Porra T, et al
    Effects of the intraoral scanner and implant library on the trueness of digital impressions in the full-arch implant scan: A comparative in vitro study.
    J Dent. 2024;150:105336.
    PubMed     Abstract available


  77. MALDONADO P, Donmez MB, Guven ME, Schimmel M, et al
    Digital analysis of fabrication accuracy and fit in additively and subtractively manufactured implant-supported fixed complete dentures.
    J Dent. 2024;150:105332.
    PubMed     Abstract available


  78. GUO H, Jiang X, Lin Y
    Comparison of robotic system and dynamic navigation for zygomatic implant placement: An in vitro study.
    J Dent. 2024;150:105329.
    PubMed     Abstract available


  79. ANSARIFARD E, Mosaddad SA, Zabihi M, Taghva M, et al
    Effect of cut-out rescanning protocol on the accuracy of digital impressions in convergent implants positioned at varying depths: An in vitro study.
    J Dent. 2024;150:105325.
    PubMed     Abstract available


  80. CANULLO L, Savadori P, Triestino A, Pesce P, et al
    Investigation of the extent of post-extraction bone contraction and remodeling after 4 months. A prospective pilot study.
    J Dent. 2024;150:105337.
    PubMed     Abstract available


  81. GOMEZ-POLO M, Cascos R, Ortega R, Barmak AB, et al
    Influence of scanning pattern on accuracy, time, and number of photograms of complete-arch implant scans: A clinical study.
    J Dent. 2024;150:105310.
    PubMed     Abstract available


  82. TIAN J, Jung RE, Han Y, Mei Y, et al
    The impact of mandibular partial edentulous distal extension on virtual occlusal record accuracy when using two different intraoral scanners: An in vitro analysis.
    J Dent. 2024;150:105303.
    PubMed     Abstract available


    October 2024
  83. FAN YY, Li S, Cai YJ, Wei T, et al
    Smoking in relation to early dental implant failure: A systematic review and meta-analysis.
    J Dent. 2024 Oct 9:105396. doi: 10.1016/j.jdent.2024.105396.
    PubMed     Abstract available


  84. LOPS D, Palazzolo A, Calza S, Proietto L, et al
    Guided versus freehand single implant placement: A 3-year parallel randomized clinical trial.
    J Dent. 2024;149:105317.
    PubMed     Abstract available


  85. SMIRANI R, Chantler JG, Endres J, Jung RE, et al
    Clinical outcomes of single implant supported crowns utilising the titanium base abutment: A 7.5-year prospective cohort study.
    J Dent. 2024;149:105306.
    PubMed     Abstract available


  86. RUIZ-ROMERO V, Jorba-Garcia A, Camps-Font O, Figueiredo R, et al
    Accuracy of dynamic computer-assisted implant surgery in fully edentulous patients: An in vitro study.
    J Dent. 2024;149:105290.
    PubMed     Abstract available


  87. SILVA JR, Curado TFF, Srinivasan M, Schimmel M, et al
    Mandibular overdenture retained by four one-piece titanium-zirconium mini implants: A 2-year follow-up on prosthodontic outcomes.
    J Dent. 2024;149:105266.
    PubMed     Abstract available


  88. CURADO TFF, Nascimento LN, Silva JR, de Paula MS, et al
    Mandibular overdenture retained by four one-piece titanium-zirconium mini implants: A 2-year RCT on patient-reported outcomes.
    J Dent. 2024;149:105267.
    PubMed     Abstract available


  89. SHUSTERMAN A, Nashef R, Tecco S, Mangano C, et al
    Implant placement using mixed reality-based dynamic navigation: A proof of concept.
    J Dent. 2024;149:105256.
    PubMed     Abstract available


  90. WEST N, Chapple I, Culshaw S, Donos N, et al
    BSP Implementation of prevention and treatment of peri-implant diseases - The EFP S3 level clinical practice guideline.
    J Dent. 2024;149:104980.
    PubMed     Abstract available


    September 2024
  91. QUISPE-LOPEZ N, Guadilla Y, Gomez-Polo C, Lopez-Valverde N, et al
    The influence of implant depth, abutment height and mucosal phenotype on peri?implant bone levels: A 2-year clinical trial.
    J Dent. 2024;148:105264.
    PubMed     Abstract available


  92. LI J, Dai M, Wang S, Zhang X, et al
    Accuracy of immediate anterior implantation using static and robotic computer-assisted implant surgery: A retrospective study.
    J Dent. 2024;148:105218.
    PubMed     Abstract available


  93. PUISYS A, Vindasiute-Narbute E, Razukevicius D, Akhondi S, et al
    Influence of mucosal tissue height on implant crestal bone: A 10-year follow-up of a controlled clinical trial.
    J Dent. 2024;148:105224.
    PubMed     Abstract available


  94. JORBA-GARCIA A, Ruiz-Romero V, Bara-Casaus JJ, Camps-Font O, et al
    The effect on the performance of a dynamic navigation system of superimposing a standard tessellation language (STL) file obtained with an intraoral scan on a cone beam computer tomograph (CBCT). An experimental in vitro study.
    J Dent. 2024;148:105150.
    PubMed     Abstract available


  95. RUTKUNAS V, Auskalnis L, Pletkus J
    Intraoral scanners in implant prosthodontics. A narrative review.
    J Dent. 2024;148:105152.
    PubMed     Abstract available


  96. RUTKUNAS V, Jegelevicius D, Gedrimiene A, Revilla-Leon M, et al
    Effect of 3D printer, implant analog and angulation on the accuracy of analog position in implant casts.
    J Dent. 2024;148:105135.
    PubMed     Abstract available


    August 2024
  97. XIE C, Li Y, Liu K, Liu J, et al
    A hybrid unsupervised clustering method for predicting the risk of dental implant loss.
    J Dent. 2024;149:105260.
    PubMed     Abstract available


  98. ELGARBA BM, Fontenele RC, Mangano F, Jacobs R, et al
    Novel AI-based automated virtual implant placement: Artificial versus human intelligence.
    J Dent. 2024;147:105146.
    PubMed     Abstract available


  99. CHO JH, Cakmak G, Choi J, Lee D, et al
    Deep learning-designed implant-supported posterior crowns: Assessing time efficiency, tooth morphology, emergence profile, occlusion, and proximal contacts.
    J Dent. 2024;147:105142.
    PubMed     Abstract available


  100. LIMONES A, Cascos R, Molinero-Mourelle P, Abou-Ayash S, et al
    Impact of the superimposition methods on accuracy analyses in complete-arch digital implant investigation.
    J Dent. 2024;147:105081.
    PubMed     Abstract available


    July 2024
  101. BENCZE B, Cavalcante BGN, Romandini M, Rona V, et al
    Prediabetes and poorly controlled type-2 diabetes as risk indicators for peri-implant diseases:A systematic review and meta-analysis.
    J Dent. 2024;146:105094.
    PubMed     Abstract available


  102. JORBA-GARCIA A, Bara-Casaus JJ, Camps-Font O, Figueiredo R, et al
    The influence of radiographic marker registration versus a markerless trace registration method on the implant placement accuracy achieved by dynamic computer-assisted implant surgery. An in-vitro study.
    J Dent. 2024;146:105072.
    PubMed     Abstract available


  103. ZAMORA GP, Molina-Gonzalez JM, Martinez-Marco JF, Ruiz AJO, et al
    Aesthetic outcomes of different materials for delayed, single-tooth restorations for immediately placed implants. A randomized controlled clinical trial.
    J Dent. 2024;146:105067.
    PubMed     Abstract available


  104. GIOK KC, Veettil SK, Menon RK
    Risk factors for Peri-implantitis: An umbrella review of meta-analyses of observational studies and assessment of biases.
    J Dent. 2024;146:105065.
    PubMed     Abstract available


  105. SCHWARZLER A, Ludwig B, Chitan P, Lettner S, et al
    Transfer accuracy of 3D printed versus CAD/CAM milled surgical guides for temporary orthodontic implants: A preclinical micro CT study.
    J Dent. 2024;146:105060.
    PubMed     Abstract available


  106. RUTKUNAS V, Jegelevicius D, Gedrimiene A, Auskalnis L, et al
    Effect of Different Intraoral Scanners on the Accuracy of Bite Registration in Edentulous Maxillary and Mandibular Arches.
    J Dent. 2024;146:105050.
    PubMed     Abstract available


  107. MAO Z, Bleiel H, Beuer F, Bose MWH, et al
    Occlusal changes on implant-supported single crowns with one year follow-up after loading: A systematic review and meta-analysis.
    J Dent. 2024;146:105000.
    PubMed     Abstract available


  108. ZHAO N, Du L, Lv C, Liang J, et al
    Accuracy analysis of robotic-assisted immediate implant placement: A retrospective case series.
    J Dent. 2024;146:105035.
    PubMed     Abstract available


  109. SHUSTERMAN A, Nashef R, Tecco S, Mangano C, et al
    Accuracy of implant placement using a mixed reality-based dynamic navigation system versus static computer-assisted and freehand surgery: An in Vitro study.
    J Dent. 2024;146:105052.
    PubMed     Abstract available


  110. ALKINDI S, Hamdoon Z, Aziz AM
    Effect of different impression coping and scan body designs on the accuracy of conventional versus digital implant impressions: An in vitro study.
    J Dent. 2024;146:105045.
    PubMed     Abstract available


  111. AL-JARSHA MY, Ayoub AF, Almgran MM, Liu CH, et al
    The precision of drill calibration for dynamic navigation.
    J Dent. 2024;146:105032.
    PubMed     Abstract available


  112. DIKEN TURKSAYAR AA, Demirel M, Petersmann S, Spintzyk S, et al
    Positional accuracy of a single implant analog in additively manufactured casts in biobased model resin.
    J Dent. 2024;146:105037.
    PubMed     Abstract available


  113. WANG J, Hu C, Ma X, Zhang Y, et al
    The role of oxidative stress biomarkers in the development of peri-implant disease: A systematic review and meta-analysis.
    J Dent. 2024;146:105026.
    PubMed     Abstract available


  114. TERZIOGLU B, Ayyildiz BG
    Effect of Supracrestal Tissue Height on Marginal Bone Level Changes at Platform-Switching Dental Implants Placed Crestally and Subcrestally: A Randomized Clinical-Trial.
    J Dent. 2024 Jul 1:105219. doi: 10.1016/j.jdent.2024.105219.
    PubMed     Abstract available


    June 2024
  115. HERREIRA-FERREIRA M, Bonfante EA, Conti PCR, Araujo-Junior ENS, et al
    Somatosensory alterations after single-unit dental implant immediate loading: A 1-year follow-up study.
    J Dent. 2024;147:105148.
    PubMed     Abstract available


  116. CHENG YC, Murcko L, Benalcazar-Jalkh EB, Bonfante EA, et al
    FHypervitaminosis D is correlated with adverse dental implant outcomes: a retrospective case-control study.
    J Dent. 2024 Jun 18:105137. doi: 10.1016/j.jdent.2024.105137.
    PubMed     Abstract available


  117. SHU Q, Chen D, Wang X, Liu Q, et al
    Accuracy of flapless surgery using an autonomous robotic system in full-arch immediate implant restoration: A case series.
    J Dent. 2024;145:105017.
    PubMed     Abstract available


  118. EL-SAWY MA, Donia S, Elmowafy DA
    Clinical and radiographic outcomes around 4 mandibular implant-retained overdentures in individuals with type 2 diabetes: A long-term retrospective study.
    J Dent. 2024;145:104982.
    PubMed     Abstract available


  119. CANULLO L, Pesce P, Caponio VCA, Iacono R, et al
    Effect of auxiliary geometric devices on the accuracy of intraoral scans in full-arch implant-supported rehabilitations: An in vitro study.
    J Dent. 2024;145:104979.
    PubMed     Abstract available


    May 2024
  120. LI P, Guan J, Chen J, Xu S, et al
    Trephination-based autonomous robotic surgery for dental implant placement: A proof of concept.
    J Dent. 2024 May 20:105090. doi: 10.1016/j.jdent.2024.105090.
    PubMed     Abstract available


  121. WANG DM, Liu DF, Zhao DX, Wu DY, et al
    Robot-assisted surgery for dental implant placement: a narrative review.
    J Dent. 2024 May 8:105034. doi: 10.1016/j.jdent.2024.105034.
    PubMed     Abstract available


  122. LAN D, Luo Y, Qu Y, Man Y, et al
    The three-dimensional stability and accuracy of 3D printing surgical templates: An In Vitro study.
    J Dent. 2024;144:104936.
    PubMed     Abstract available


  123. BONFANTI-GRIS M, Herrera A, Paraiso-Medina S, Alonso-Calvo R, et al
    Performance evaluation of three versions of a convolutional neural network for object detection and segmentation using a multiclass and reduced panoramic radiograph dataset.
    J Dent. 2024;144:104891.
    PubMed     Abstract available


    April 2024
  124. WANG ZY, Gong Y, Liu F, Chen D, et al
    Influence of intraoral scanning coverage on the accuracy of digital implant impressions - An in vitro study.
    J Dent. 2024;143:104929.
    PubMed     Abstract available


  125. EL OSTA N, Drancourt N, Auduc C, Veyrune JL, et al
    Accuracy of conventional impressions and digital scans for implant-supported fixed prostheses in maxillary free-ended partial edentulism: An in vitro study.
    J Dent. 2024;143:104892.
    PubMed     Abstract available


  126. GUNEY Z, Altingoz SM, Has H, Serdar MA, et al
    The impact of electronic cigarettes on peri-implant health: A systematic review and meta-analysis.
    J Dent. 2024;143:104883.
    PubMed     Abstract available


  127. NUYTENS P, Grande F, D'haese R, Salameh Z, et al
    Novel complete-arch pillar system (CAPS) to register implant position and maxillomandibular relationship in one single visit.
    J Dent. 2024;143:104885.
    PubMed     Abstract available


  128. ELGARBA BM, Fontenele RC, Tarce M, Jacobs R, et al
    Artificial intelligence serving pre-surgical digital implant planning: A scoping review.
    J Dent. 2024;143:104862.
    PubMed     Abstract available


  129. RUTKUNAS V, Bilius V, Dirse J, Revilla-Leon M, et al
    Repositioning accuracy of the implant- and abutment-level prosthetic components used in conventional and digital workflows.
    J Dent. 2024;143:104835.
    PubMed     Abstract available


    March 2024
  130. OLIVEIRA-SANTOS N, Beersingh AH, Felizardo HMA, Groppo FC, et al
    Association between maxillary sinus floor perforation by dental implants and mucosal thickening: A cone-beam computed tomography study.
    J Dent. 2024;144:104963.
    PubMed     Abstract available


  131. BASAK SS, Guler B, Eken S, Akcan SK, et al
    Radiographic Evaluation of The Distance Between The Restoration Margin and The Alveolar Bone Crest in Dental Implant Patients: A Retrospective Study.
    J Dent. 2024 Mar 16:104935. doi: 10.1016/j.jdent.2024.104935.
    PubMed     Abstract available


  132. WU Z, Yu X, Wang F, Xu C, et al
    Application of artificial intelligence in dental implant prognosis: A scoping review.
    J Dent. 2024;144:104924.
    PubMed     Abstract available


  133. GUL A, Papia E, Naimi-Akbar A, Ruud A, et al
    Zirconia dental implants; the relationship between design and clinical outcome: A systematic review.
    J Dent. 2024 Mar 2:104903. doi: 10.1016/j.jdent.2024.104903.
    PubMed     Abstract available


  134. REVILLA-LEON M, Gomez-Polo M, Drone M, Barmak AB, et al
    Impact of scanning distance on the accuracy of a photogrammetry system.
    J Dent. 2024;142:104854.
    PubMed     Abstract available


    January 2024
  135. WU HK, Chen G, Zhang Z, Lin X, et al
    Effect of artificial landmarks of the prefabricated auxiliary devices located at different arch positions on the accuracy of complete-arch edentulous digital implant scanning: An in-vitro study.
    J Dent. 2024;140:104802.
    PubMed     Abstract available


  136. LUONGO F, Lerner H, Gesso C, Sormani A, et al
    Accuracy in static guided implant surgery: Results from a multicenter retrospective clinical study on 21 patients treated in three private practices.
    J Dent. 2024;140:104795.
    PubMed     Abstract available


  137. WU HK, Chen G, Wang J, Zhang Z, et al
    Effect of prefabricated auxiliary devices and scanning patterns on the accuracy of complete-arch implant digital impressions.
    J Dent. 2024;140:104788.
    PubMed     Abstract available


    December 2023
  138. PAN Y, Dai X, Wan F, Song C, et al
    A novel post-processing strategy to improve the accuracy of complete-arch intraoral scanning for implants: an in vitro study.
    J Dent. 2023;139:104761.
    PubMed     Abstract available


  139. TAKACS A, Hardi E, Cavalcante BGN, Szabo B, et al
    Advancing accuracy in guided implant placement: A comprehensive meta-analysis: Meta-Analysis evaluation of the accuracy of available implant placement Methods.
    J Dent. 2023;139:104748.
    PubMed     Abstract available


  140. KLEIN M, Tuminelli FJ, Sallustio A, Giglio GD, et al
    Full-arch restoration with the NEXUS IOS(R) system: A retrospective clinical evaluation of 37 restorations after a one year of follow-up.
    J Dent. 2023;139:104741.
    PubMed     Abstract available


  141. DONMEZ MB, Guven ME, Yilmaz D, Abou-Ayash S, et al
    Trueness and precision of combined healing abutment scan body system scans at different sites of maxilla after multiple repositioning of the scan body.
    J Dent. 2023;139:104716.
    PubMed     Abstract available


  142. RUTKUNAS V, Gendviliene I, Auskalnis L, Mangano F, et al
    Influence of Kennedy class and number of implants on the accuracy of dynamic implant navigation: An in vitro study using an X-ray free evaluation methodology.
    J Dent. 2023;139:104679.
    PubMed     Abstract available


    November 2023
  143. IEZZI G, Zavan B, Petrini M, Ferroni L, et al
    3D PRINTED DENTAL IMPLANTS WITH A POROUS STRUCTURE: THE IN VITRO RESPONSE OF OSTEOBLASTS, FIBROBLASTS, MESENCHYMAL STEM CELLS, AND MONOCYTES.
    J Dent. 2023 Nov 9:104778. doi: 10.1016/j.jdent.2023.104778.
    PubMed     Abstract available


  144. DONMEZ MB, Cakmak G, Dede DO, Kucukekenci AS, et al
    Effect of scan powder and scanning technology on measured deviations of complete-arch implant supported frameworks digitized with industrial and intraoral scanners.
    J Dent. 2023;138:104736.
    PubMed     Abstract available


  145. LIM TW, Pan H, Pan M, Burrow MF, et al
    Agreement in quantification of removable prosthesis plaque area coverage using a semi-automated planimetric assessment method.
    J Dent. 2023;138:104721.
    PubMed     Abstract available


  146. NUYTENS P, Vandeweghe S, D'haese R
    Accuracy of a chairside reverse scanbody workflow for a complete arch implant-supported prosthesis using four intraoral scanners versus a desktop scanner.
    J Dent. 2023;138:104717.
    PubMed     Abstract available


  147. DENG H, Bian H, Liang Y, Cao J, et al
    Semi-autonomous two-stage dental robotic technique for zygomatic implants: An in vitro study.
    J Dent. 2023;138:104687.
    PubMed     Abstract available


  148. WU HK, Chen G, Huang X, Deng F, et al
    Accuracy of single-implant digital impression with various scanbody exposure levels at anterior and posterior regions.
    J Dent. 2023;138:104641.
    PubMed     Abstract available


    October 2023
  149. ZHOU Q, Fei Y, Li N, Ren YF, et al
    Healing Outcomes of Open versus Closed Flap Procedures for Collagen Membrane Coverage following Immediate Dental Implant Placements with Simultaneous Guided Tissue Regeneration.
    J Dent. 2023 Oct 5:104735. doi: 10.1016/j.jdent.2023.104735.
    PubMed     Abstract available


  150. MIJIRITSKY E, Elad A, Krausz R, Ivanova V, et al
    Clinical performance of full-arch implant-supported fixed restorations made of monolithic zirconia luted to a titanium bar: A retrospective study with a mean follow-up of 16 months.
    J Dent. 2023;137:104675.
    PubMed     Abstract available


  151. WANG J, Wu YL, Ma J, Wu F, et al
    A novel technique for implant-supported fixed complete rehabilitation based on a dynamic virtual patient.
    J Dent. 2023;137:104649.
    PubMed     Abstract available


  152. SHRIVASTAVA R, Luxenberg R, Sutton E, Emami E, et al
    Patients experience and satisfaction with immediate loading of implant-supported overdentures - A qualitative study.
    J Dent. 2023;137:104644.
    PubMed     Abstract available


    September 2023
  153. GUPTA R, Gupta N, Weber, DDS KK, Bruhnke M, et al
    Implant or tooth? - A cost-time analysis of managing "unrestorable" teeth(✰).
    J Dent. 2023;136:104646.
    PubMed     Abstract available


  154. KOMAGAMINE Y, Kanazawa M, Miyayasu A, Uehara Y, et al
    The effect of single-implant overdentures on cognitive function in older adults: A 3-year follow-up report.
    J Dent. 2023;136:104632.
    PubMed     Abstract available


  155. FAOT F, Petiz HCFC, Bielemann AM, Possebon APDR, et al
    Functional performance and impact on the quality of life of three treatment strategies for mandibular edentulism: Results of a parallel 3-group cross-sectional study.
    J Dent. 2023;136:104625.
    PubMed     Abstract available


  156. CHANDRAN K R S, Goyal M, Mittal N, George JS, et al
    Accuracy of freehand versus guided immediate implant placement: A randomized controlled trial.
    J Dent. 2023;136:104620.
    PubMed     Abstract available


  157. KOFINA V, Monfaredzadeh M, Rawal SY, Dentino AR, et al
    Patient-reported outcomes following guided bone regeneration: Correlation with clinical parameters.
    J Dent. 2023;136:104605.
    PubMed     Abstract available


    August 2023
  158. MA S, Bai C, Chen C, Bai J, et al
    Public sense of dental implants on social media: A cross-sectional study based on text analysis of comments.
    J Dent. 2023 Aug 19:104671. doi: 10.1016/j.jdent.2023.104671.
    PubMed     Abstract available


  159. SHERIGAR SR, Feine JS, Cooper LF, Stanford CM, et al
    Can patients detect peri‑implant mucosal inflammation? Results from a multicentre randomized trial.
    J Dent. 2023;135:104592.
    PubMed     Abstract available


  160. YU X, Tao B, Wang F, Wu Y, et al
    Accuracy assessment of dynamic navigation during implant placement: A systematic review and meta-analysis of clinical studies in the last 10 years.
    J Dent. 2023;135:104567.
    PubMed     Abstract available


  161. KE Y, Zhang Y, Wang Y, Chen H, et al
    Comparing the accuracy of full-arch implant impressions using the conventional technique and digital scans with and without prefabricated landmarks in the mandible: An in vitro study.
    J Dent. 2023;135:104561.
    PubMed     Abstract available


    July 2023
  162. ELGARBA BM, Van Aelst S, Swaity A, Morgan N, et al
    Deep learning-based segmentation of dental implants on cone-beam computed tomography images: A validation study.
    J Dent. 2023 Jul 28:104639. doi: 10.1016/j.jdent.2023.104639.
    PubMed     Abstract available


  163. XU Z, Xiao Y, Zhou L, Lin Y, et al
    Accuracy and efficiency of robotic dental implant surgery with different human-robot interactions: An in vitro study.
    J Dent. 2023 Jul 28:104642. doi: 10.1016/j.jdent.2023.104642.
    PubMed     Abstract available


  164. ZHAO Y, Liao Y, Wu X, Zhang Y, et al
    Effect of the number and distribution of fiducial markers on the accuracy of robot-guided implant surgery in edentulous mandibular arches: An in vitro study.
    J Dent. 2023;134:104529.
    PubMed     Abstract available


    June 2023
  165. CHIH SM, Cheng CD, Chen SH, Sung CE, et al
    The impact of smoking on peri-implant microbiota: A systematic review.
    J Dent. 2023;133:104525.
    PubMed     Abstract available


  166. MANGANO FG, Admakin O, Lerner H, Mangano C, et al
    Artificial intelligence and augmented reality for guided implant surgery planning: A proof of concept.
    J Dent. 2023;133:104485.
    PubMed     Abstract available


    May 2023
  167. ROTHLAUF S, Pieralli S, Wesemann C, Burkhardt F, et al
    Influence of planning software and template design on the accuracy of static computer assisted implant surgery performed using guides fabricated with material extrusion technology: An in vitro study.
    J Dent. 2023;132:104482.
    PubMed     Abstract available


  168. HAROYAN-DARBINYAN E, Romeo-Rubio M, Rio-Highsmith JD, Lynch CD, et al
    'Thermo-mechanical behavior of alternative material combinations for full-arch implant-supported hybrid prostheses with short cantilevers'.
    J Dent. 2023;132:104470.
    PubMed     Abstract available


  169. YANG S, Chen J, Li A, Deng K, et al
    Accuracy of autonomous robotic surgery for single-tooth implant placement: A case series.
    J Dent. 2023;132:104451.
    PubMed     Abstract available


    March 2023
  170. TAHERI OTAGHSARA SS, Joda T, Thieringer FM
    Accuracy of dental implant placement using static versus dynamic computer-assisted implant surgery: An in vitro study.
    J Dent. 2023;132:104487.
    PubMed     Abstract available


  171. BHALERAO A, Marimuthu M, Wahab A, Ayoub A, et al
    Dynamic navigation for zygomatic implant placement: A randomized clinical study comparing the flapless versus the conventional approach.
    J Dent. 2023;130:104436.
    PubMed     Abstract available


  172. POMARES-PUIG C, Sanchez-Garces MA, Jorba-Garcia A
    Dynamic and static computer-assisted implant surgery for completely edentulous patients. A proof of a concept.
    J Dent. 2023;130:104443.
    PubMed     Abstract available


  173. DULLA FA, Couso-Queiruga E, Chappuis V, Yilmaz B, et al
    Influence of alveolar ridge morphology and guide-hole design on the accuracy of static Computer-Assisted Implant Surgery with two implant macro-designs: An in vitro study.
    J Dent. 2023;130:104426.
    PubMed     Abstract available


  174. MIOTK N, Schwindling FS, Zidan M, Juerchott A, et al
    Reliability and accuracy of intraoral radiography, cone beam CT, and dental MRI for evaluation of peri-implant bone lesions at zirconia implants - an ex vivo feasibility study.
    J Dent. 2023;130:104422.
    PubMed     Abstract available


  175. CAKMAK G, Donmez MB, Akay C, de Paula MS, et al
    Effect of measurement techniques and operators on measured deviations in digital implant scans.
    J Dent. 2023;130:104388.
    PubMed     Abstract available


    January 2023
  176. KOBE T, Fidler A, Kuralt M, Gaspirc B, et al
    Retentive design of a small surgical guide for implant surgery: An in-vitro study.
    J Dent. 2023;128:104384.
    PubMed     Abstract available


  177. MO S, Xu Y, Zhang L, Cao Y, et al
    Accuracy of a 3D printed sleeveless guide system used for fiber post removal: An in vitro study.
    J Dent. 2023;128:104367.
    PubMed     Abstract available


    December 2022
  178. LIDANI R, Sabatini GP, Santos TTO, Floriani F, et al
    Impact of the extension of the anterior-posterior spread on quality of life and satisfaction of patients treated with implant-retained mandibular overdentures - a randomized clinical trial.
    J Dent. 2022;127:104346.
    PubMed     Abstract available


  179. ABOU-AYASH S, Mathey A, Gaumann F, Mathey A, et al
    In vitro scan accuracy and time efficiency in various implant-supported fixed partial denture situations.
    J Dent. 2022;127:104358.
    PubMed     Abstract available


  180. HERRERO F, de Souza RF, Feine JS, Alexander PP, et al
    The impact of implant-retained overdentures on type-2 diabetic and non-diabetic edentulous patients: Satisfaction and quality of life in a prospective cohort study.
    J Dent. 2022;127:104357.
    PubMed     Abstract available


  181. CHANDRAN S, Sers L, Picciocchi G, Luongo F, et al
    Guided implant surgery with R2Gate(R): A multicenter retrospective clinical study with 1 year of follow-up.
    J Dent. 2022;127:104349.
    PubMed     Abstract available


  182. MANGANO C, Luongo G, Luongo F, Lerner H, et al
    Custom-made computer-aided-design/ computer-assisted-manufacturing (CAD/CAM) synthetic bone grafts for alveolar ridge augmentation: A retrospective clinical study with 3 years of follow-up.
    J Dent. 2022;127:104323.
    PubMed     Abstract available


    November 2022
  183. SP H, A B, Pr S
    Radiographic results of osteotome-driven maxillary sinus floor elevation without grafting materials after 17.5 years radiographic evaluation of minimally-invasive sinus grafting.
    J Dent. 2022;126:104318.
    PubMed     Abstract available


  184. RUTKUNAS V, Bilius V, Simonaitis T, Auskalnis L, et al
    The effect of different implant impression splinting techniques and time on the dimensional accuracy: An in vitro study.
    J Dent. 2022;126:104267.
    PubMed     Abstract available


    October 2022
  185. PLETKUS J, Rutkunas V, Gendviliene I, Borusevicius R, et al
    Model-free digital workflow and immediate functional loading of implant-supported monolithic glass-ceramic crowns: A case series.
    J Dent. 2022;125:104270.
    PubMed     Abstract available


  186. KANJANASAVITREE P, Thammajaruk P, Guazzato M
    Comparison of different artificial landmarks and scanning patterns on the complete-arch implant intraoral digital scans.
    J Dent. 2022;125:104266.
    PubMed     Abstract available


  187. JIN G, Shin SH, Shim JS, Lee KW, et al
    Accuracy of 3D printed models and implant-analog positions according to the implant-analog-holder offset, inner structure, and printing layer thickness: an in-vitro study.
    J Dent. 2022;125:104268.
    PubMed     Abstract available


    September 2022
  188. SANZ E, Azabal M, Arias A
    Quality of life and satisfaction of patients two years after endodontic and dental implant treatments performed by experienced practitioners.
    J Dent. 2022 Sep 5:104280. doi: 10.1016/j.jdent.2022.104280.
    PubMed     Abstract available


  189. DONMEZ MB, Cakmak G, Atalay S, Yilmaz H, et al
    Trueness and precision of combined healing abutment-scan body system depending on the scan pattern and implant location: An in-vitro study.
    J Dent. 2022;124:104169.
    PubMed     Abstract available


    August 2022
  190. BOSE MWH, Beuer F, Schwitalla A, Bruhnke M, et al
    Dynamic navigation for dental implant placement in single-tooth gaps: A preclinical pilot investigation.
    J Dent. 2022;125:104265.
    PubMed     Abstract available


  191. FIGUERAS-ALVAREZ O, Clua-Palau A, Caponi LQ, Vidal-Ponsoda C, et al
    Interarch space assessment in edentulous patients rehabilitated with complete removable dentures using open-access software.
    J Dent. 2022;123:104127.
    PubMed     Abstract available


    July 2022
  192. WANG XY, Liu L, Guan MS, Liu Q, et al
    The accuracy and learning curves of active and passive dynamic navigation-guided dental implant surgery: An in vitro study.
    J Dent. 2022 Jul 21:104240. doi: 10.1016/j.jdent.2022.104240.
    PubMed     Abstract available


    June 2022
  193. TAO B, Feng Y, Fan X, Zhuang M, et al
    Accuracy of dental implant surgery using dynamic navigation and robotic systems: An in vitro study.
    J Dent. 2022 Jun 6:104170. doi: 10.1016/j.jdent.2022.104170.
    PubMed     Abstract available


  194. PISTILLI R, Canullo L, Pesce P, Pistilli V, et al
    Guided implant surgery and sinus lift in severely resorbed maxillae: A retrospective clinical study with up to 10 years of follow-up.
    J Dent. 2022;121:104137.
    PubMed     Abstract available


  195. GOMEZ-POLO M, Alvarez F, Ortega R, Gomez-Polo C, et al
    Influence of the implant scan body bevel location, implant angulation and position on intraoral scanning accuracy: An in vitro study.
    J Dent. 2022;121:104122.
    PubMed     Abstract available


    April 2022
  196. POZZI A, Arcuri L, Lio F, Papa A, et al
    Accuracy of complete-arch digital implant impression with or without scanbody splinting: An in vitro study.
    J Dent. 2022;119:104072.
    PubMed     Abstract available


  197. GRECCHI E, Stefanelli LV, Grecchi F, Grivetto F, et al
    A novel guided zygomatic implant surgery system compared to free hand: A human cadaver study on accuracy.
    J Dent. 2022;119:103942.
    PubMed     Abstract available


    March 2022
  198. BERTACCO M, Soyeux O, Durand R, Boudrias P, et al
    Effect of Personalized Musical Intervention on Burden of Care in Dental Implant Surgery: A Pilot Randomized Controlled Trial.
    J Dent. 2022 Mar 10:104091. doi: 10.1016/j.jdent.2022.104091.
    PubMed     Abstract available


  199. DONMEZ MB, Marques VR, Cakmak G, Yilmaz H, et al
    Congruence between the meshes of a combined healing abutment-scan body system acquired with four different intraoral scanners and the corresponding library file: An in vitro analysis.
    J Dent. 2022;118:103938.
    PubMed     Abstract available


    February 2022
  200. PAN Y, Heng C, Wu ZJ, Tam J, et al
    Comparison of the virtual techniques in registering single implant position with a universal-coordinate system: An in vitro study.
    J Dent. 2022;117:103925.
    PubMed     Abstract available


  201. UEHARA Y, Kanazawa M, Miyayasu A, Watanabe M, et al
    Comparison of general satisfaction, oral health-related quality of life, and patient's self-assessment between mandibular single-implant overdentures and experimental removable complete dentures: A randomized crossover clinical trial.
    J Dent. 2022;117:103920.
    PubMed     Abstract available


    January 2022
  202. OKUNI S, Maekawa K, Mino T, Kurosaki Y, et al
    A retrospective comparison of the survival of vital teeth adjacent to single, bounded edentulous spaces rehabilitated using implant-supported, resin-bonded, and conventional fixed dental prostheses.
    J Dent. 2022;116:103911.
    PubMed     Abstract available


  203. HAROYAN-DARBINYAN E, Romeo-Rubio M, Rio-Highsmith JD, Lynch CD, et al
    Fracture resistance of cantilevered full-arch implant-supported hybrid prostheses with carbon fiber frameworks after thermal cycling.
    J Dent. 2022;116:103902.
    PubMed     Abstract available


    December 2021
  204. WANG ZY, Chao JR, Zheng JW, You M, et al
    The influence of crown coverage on the accuracy of static guided implant surgery in partially edentulous models: An in vitro study.
    J Dent. 2021;115:103882.
    PubMed     Abstract available


  205. POSSEBON APDR, Schuster AJ, Chagas-Junior OL, Pinto LR, et al
    Prosthetic aftercare, mastication, and quality of life in mandibular overdenture wearers with narrow implants: A 3-year cohort study.
    J Dent. 2021;115:103880.
    PubMed     Abstract available


  206. ATALAY S, Cakmak G, Donmez MB, Yilmaz H, et al
    Effect of implant location and operator on the accuracy of implant scans using a combined healing abutment-scan body system.
    J Dent. 2021;115:103855.
    PubMed     Abstract available


  207. TALLARICO M, Czajkowska M, Cicciu M, Giardina F, et al
    Accuracy of surgical templates with and without metallic sleeves in case of partial arch restorations: A systematic review.
    J Dent. 2021;115:103852.
    PubMed     Abstract available


  208. NOGUEIRA TE, Silva JR, Nascimento LN, Cardoso JB, et al
    Immediately loaded single-implant mandibular overdentures compared to conventional complete dentures: A cost-effectiveness analysis.
    J Dent. 2021;115:103846.
    PubMed     Abstract available


Thank you for your interest in scientific medicine.


AMEDEO Dental Implants is free of charge.